m51a350xx4640| Datasheet
Datasheet preview, take a look at Datasheets before downloading (Data Sheet is available on manufacturer site)
Surge Arrester 2-Electrode-Arrester
M51-A350X Ordering code: B88069X4640C102
DC spark-over voltage 1) 2) Impulse spark-over voltage at 100 V/us - for 99 % of measured values - typical values of distribution at 1 kV/us - for 99 % of measured values - typical values of distribution
350 20 < 800 < 750 < 900 < 800 5 10 5 10 >1 <1 ~ 20 ~ 0.8 ~ 65 ~1 -40 ... +90 40/ 90/ 21 350 YY O
350 YY O - Nominal voltage - Year of production - Non radioactive
V % V V V V kA kA A A G pF V A V g C
Nominal impulse discharge current (wave 8/20 us) Single impulse discharge current (wave 8/20 us) Nominal alternating discharge current (50 Hz, 1 s) Alternating discharge current (50 Hz, 9 cycles) Insulation resistance at 100 Vdc Capacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltage Weight Operation and storage temperature Climatic category (IEC 60068-1) Marking, blue
1) 2)
At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM Page 1 of 2
Issue 02, 24.04.2002
m51a350xx4640 Datasheet epcos Download PDF
Add this permalink to your bookmarks for future download of m51a350xx4640 datasheet
Permalink: http://datasheet.emcelettronica.com/epcos/m51a350xx4640