KA2803B

www.fairchildsemi.com

Datasheet preview, take a look at Datasheets before downloading (Data Sheet is available on manufacturer site)

www.fairchildsemi.com

KA2803B

Earth Leakage Detector
Features
Low Power Consumption PD 5mW, 100V/200V Built-in Voltage Regulator High Gain Differential Amplifier 0.4mA Output Current Pulse to Trigger SCR S Low External Part Count DIP Package (8-DIP), High Packing Density High Noise Immunity, Large Surge Margin Super Temperature Characteristic of Input Sensitivity Wide Operating Temperature Range (TA -25 C 80 C) Operation from 12 to 20V Input

Description
The KA2803B is designed for use in earth leakage circuit interrupters, for stable operation of the AC line in breakers. The input of the differential amplifier is connected to the secondary coil of ZCT(Zero Current Transformer). The amplified output of differential amplifier is integrated at external capacitor to gain adequate time delay that is specified in KSC4613. The level comparator generates high level when earth leakage current is greater than the fixed level.
8-DIP

Functions
Differential Amplifier Level Comparator Latch Circuit
1

8-SOP
1

Block Diagram
8
VCC

7

OS(Output)

6

NR

5

SC

Bias Voltage

Internal Internal Bias

Zener Zener Protect

Reference Voltage Generator Reference

Latch Latch Circuit

-

Circuit

Voltage

1

VR

2

VI

3

GND

4

OD

Rev. 1.0.4
2002 Fairchild Semiconductor Corporation

KA2803B Datasheet Fairchild Download PDF

Add this permalink to your bookmarks for future download of KA2803B datasheet

Permalink: http://datasheet.emcelettronica.com/fairchild/KA2803B

-->