bp5041a| Datasheet
Datasheet preview, take a look at Datasheets before downloading (Data Sheet is available on manufacturer site)
AC220V input, 12V/100mA output
Non-isolated AC/DC converter
BP5041A
Absolute Maximum Ratings
Parameter Input voltage Output current ESD enduration Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits 390 100 2 -25 to +80 -25 to +105 Unit V mApk kV C C
32.5MAX. 11.5MAX.
Dimension(Unit : mm)
Mark Side
1 3 5 7 0.5 0.1 1.3 0.2 3.25MAX. P=5.08 0.2 22.86 6.75MAX. 10 0 . 2 5 0 . 0 5 4.75MAX.
Electrical Characteristics
Symbol Min. Parameter Input voltage range 226 Vi Output voltage 11.0 Vo Output current 0 Io Line regulation - Vr Load regulation - Vl Output ripple voltage - Vp Power conversion effciency 50 Typ. 282 12.0 - 0.02 0.05 0.05 62 Max. 390 13.0 100 0.15 0.15 0.15 - Unit V V mA V V Vp-p % Conditions DC(160 to 276VAC) Vi=282V, Io=50mA Vi=282V 1 Vi=226 to 390V, Io=50mA Vi=282V, Io=0 to 50mA 2 Vi=282V, Io=50mA Vi=282V, Io=100mA 2
Derating Curve
120 Derating Curve
Output Current Io(mA)
100 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta( C) Operation Range
1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. 2 Please refer to Load regulation, Conversion effciency.
Switching Frequency
Switching Frequency fsw (kHz)
45 40 35 30 25 20 15 10 5 0 0 Switching Frequency (Ta=25 C, Vi=282V)
Application circuit
BP5041A
Please note that pin No.10 side is input.
Pin No. 1 2 3 4 5 6 7 8 9 10 Function Output terminal Vo(12V) Not used N.C. Not used COMMON Not used N.C. Not used Not used Input terminal Vi(141VDC)
4 1.0
19.3MAX.
20 40 60 80 Output Current Io(mA)
100
Conversion Efficiency
Conversion Efficiency (%)
100 80 60 40 20 0 0 20 40 60 80 Output Current Io(mA) 100 Conversion Efficiency (Ta=25 C, Vi=282V)
10
D1 Input AC200V 50Hz/60Hz ZNR + R1 101/4W FUSE 0.5A C2 0.1uF
7
5
3
1
Output +12V
-
C1 4.7uF/450V
+
C3
- 100uF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product, Especially, Please make sure to confirm whether the load current exceed Max. rated current by using the current probe. External components setting C1: Capacitor for input voltage smoothing C2: For noise terminal voltage reduction C3: Capacitor for Output voltage smooting D1: Rectifier diode Capacitance : 3.3uF to 22uF Rated voltage : 450V or higher Ripple current is 0.13Arms above. Capacitance : 0.1uF to 0.22uF Rated voltage : 400V or higher Film capacitor or ceramic capacitor. Reduce the noise terminal voltage. The constant value should be evaluated in the set. Capacitance : 100uF to 470uF Rated voltage : 25V or higher, ESR is 0.39 max. Ripple current is 0.1Arms above. Output noise voltage is influenced.Please evaluate it in the actual set. In the absolute maximum ratings, the reverse peak voltage should be 800V or higher, the average rectifying current should be 0.5A or higher, and the peak surge current should be 20A o
r higher. (Full-wave rectifier can be used in out part.) 10 to 22 1/4W Reduce the noise terminal voltage.The constant value should be evaluated in set. Varistor must be used. It protects this part from lightning surge and static electricity.
Load Regulation
Output Voltage Vo( C)
FUSE: Fuse
Please make sure to use quick acting fuse 0.5A
13.0 12.8 12.6 12.4 12.2 12.0 11.8 11.6 11.4 11.2 11.0
Load Regulation (Ta=25 C, Vi=282V)
0
20 40 60 80 Output Current Io(mA)
100
Surface Temperature Rising
Temperature Rising T( C)
50 40 30 20 10 0
0
Surface Temperature Rising (Ta=25 C,Vi=282V)
R1: For noise terminal voltage reduction ZNR: Varistor
20 40 60 80 Output Current Io(mA)
100
www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved.
1/1
2009.01 - Rev.A